Worked 200 mm rise at 45°: 282.84 mm slope, 200 mm horizontal reach and 82.84 mm V-notch for a 300 × 100 mm tray. Includes editable 3D.
The available horizontal run is 700 mm; it includes the lead-in and slope projection, and excludes the final tail.
Calculated answer at a glance
A 200 mm rise at 45° requires an ideal sloped base length of 282.84 mm. It occupies 200 mm horizontally, leaving a 500 mm lead-in inside the stated 700 mm run.
Form: close A and open B to level the tail. Toggle the purple connection cover to inspect the opening.
Cutting layout · continuous-base method
Side-wall layout, repeated on both sides. A is the closing bend; B is the opening bend. Stations are measured along the straight base from its starting end.
Notch height and small openings are enlarged for readability. Use the labelled dimensions; do not measure from the screen.
● Keep base connected
━ Cut side walls┄ Base fold axis■ Removed material■ Connection cover
At A, remove the V from both walls and fold upward until its edges meet. At B, slit both walls to the base, then counter-fold to make the tail horizontal. The walls open at B: provide a compatible connection detail; purple shows the gap-cover region, not a specified fastener or plate design.
Ideal thin-sheet geometry: excludes kerf, bend radius, rolled lips, material allowance and connection specifications. This method keeps the base joined at both axes; do not cut across it.
Help improve this toolSomething unclear, a result to check, or a feature you need? Tell us.Send feedback +
TrayNeo · Calculation summary
Cable Tray Vertical Offset Calculator & 3D Guide
Geometric estimate and illustrative process. Not a fabrication drawing.
Plan your rise
Rise height
200.00 mm
Bend angle
45°
Tray width
300.00 mm
Side height
100.00 mm
Available horizontal run
700.00 mm
Geometry results
Sloped length
282.84 mm
Horizontal reach
200.00 mm
Lead-in distance
500.00 mm
Cutting layout · continuous-base method
V half-width d
41.42 mm
V full width 2d
82.84 mm
A / B
500.00 mm / 782.84 mm
At A, remove the V from both walls and fold upward until its edges meet. At B, slit both walls to the base, then counter-fold to make the tail horizontal. The walls open at B: provide a compatible connection detail; purple shows the gap-cover region, not a specified fastener or plate design.
Ideal thin-sheet geometry: excludes kerf, bend radius, rolled lips, material allowance and connection specifications. This method keeps the base joined at both axes; do not cut across it.
How the geometry is calculated
For rise H and angle θ: sloped length = H / sin(θ); horizontal reach = H / tan(θ); lead-in = available run − horizontal reach. Angles are in degrees. These are ideal geometric lengths, not bend allowances.
Reproduce the calculation
S = 200 / sin(45°) = 282.84 mm. Q = 200 / tan(45°) = 200 mm. A = 700 − Q = 500 mm. B = A + S = 782.84 mm.
2d = 2 × 100 × tan(45° / 2) = 82.84 mm.
Read the two different distances
B = 782.84 mm is measured along the original straight base. The 700 mm run is a horizontal projection of the formed tray. They are different measurements, so do not put the projected run onto the straight blank as station B. The model tail is 200 mm and is excluded from that run.
Section size and fabrication limits
The 100 mm wall height controls the notch opening; the 300 mm base width sets the cross-section. These ideal geometric lengths apply independently of material choice, but they do not establish that galvanized steel, stainless steel or FRP can use the same cutting and folding process. Bend radius, kerf, rolled lips, material allowance and connection hardware require a suitable fabrication method.